Fragrances & Flavours

Dosing valve cluster
For large production runs from over 1,000 kg up to 2,000–3,000 kg,
a dosing valve cluster can be installed at the end of the dosing line.
This requires a free corridor of approximately 3 metres
and only a short extension of the existing piping.
A 50 cm diameter cluster can accommodate approximately
40 valves, using a combination of 1″ and 1½″ valves.
Using the same robotic system, with sliding gearboxes
moving along a circular path, all valves can be actuated
while maintaining both full-pipe and drop-by-drop dosing.
At these batch sizes, drop-by-drop control is less critical
because of the high precision of large-capacity scales.
A 2,000–3,000 kg scale can be installed flush with the floor,
while a mobile AMR equipped with a 500–1,000 kg scale
can position itself directly above it when required.
With suitable piping and operating conditions,
a 1½″ line can achieve flow rates of up to approximately 500 L/min,
providing very high throughput.
High-Flow Valve Cluster for Large Batches
Dosing Valve Cluster